M3100 Mobile to Table-Top Convertible Anesthesia Machine
- Can be used with mobile base or as a table-top machine. Easily removable pins secure anesthesia machine to shelf on caster base.
- 0-4 LPM O2 flow meter with mechanical stop flow control
*Other carrier gas and LPM range flow meters available upon request. - Oxygen flush with industry standard 30 LPM safety restrictor
- Non-rebreathing design is for use with mice, rats or other small mammals.
- Compatible with any vaporizer
- Shown with optional IV Pole
- Oxygen cylinders not included. Optional Dual E-tank Yoke Available.
- Ten Year Manufacturer’s Warranty on Anesthesia Machine / 3 Year Warranty on Vaporizer
|
Related products
- 0 to 4 lpm flow meter w/ expanded 0 to 1 scale & Flush
- Isoflurane Vaporizer w/ Inlet and Outlet adapters
- One rat/mouse nose cone circuit w/ adjustable diaphragm
- Dual Induction Kit with induction chamber and a pressure-equalized dual/splitter valve
- Hoses & connectors for nose cone & chamber
- Two scavenger circuits w/ replaceable evacuation filter cartridges
- Optional 4 or 6 Way splitter manifolds available
- 10 year warranty on machine, 3 year on vaporizer
- Made in USA.
- This proven anesthetic vaporizer offers excellent performance *Especially with low flows.
- *Internationally recognized, award-winning design.
- 4.8 kg Low weight for easy use.
- Service-free vaporizer designed for years of regular use with without preventive maintenance services
- Capacity Volume: at MAX mark 250 mL nominal
- Volume at MIN mark: 35 ±10 mL – After draining, Approx. 60 ±10 mL of liquid is retained by the wick
- Flow Range: Operating flow range 0.2 to 15 liters/min
- Temperature Range: Operating temperature range 15° to 35°C (58° to 95°F)
Table Top Rodent Anesthesia Machine w/ Chamber & Nose Cone
Complete System Includes:
* Optional accessories include an oxygen supply hose and anti-spill adapter
V3000PK | Rodent Table Top Anesthesia Machine – Complete System for Multiple Subjects | $3,085.00 |
|
Penlon Sigma Delta Anesthetic Vaporizer
Calibrated dials with precision output not affected by temperature, flow rate, liquid level or back pressure fluctuation. It is recommended that a service is carried out at ten years.
Includes:
|
F/AIR Scavenger System
This economical and practical passive scavenger system incorporates replaceable filter cartridges to absorb waste gases. Activated charcoal filter absorbs 125% of its own weight. Kit includes one cartridge, scavenger hose, Pop-off connection adapters, and cartridge holder bracket.
|
Model 2000 and 2002 VENTILATORS
Electronically controlled, time-cycled, pressure limited ventilators.
Electronic control– Eliminates the substantial driving gas required to operate pneumatically controlled ventilators.
Time cycled– Insures consistently spaced breaths. The possibility of stacking breaths or auto-PEEP is eliminated by keeping the I:E ratio constant at 1:2. This means that regardless of the respiratory rate setting two-thirds of each breath will remain for expiration. The respiratory rate is adjustable from 6 – 40 breaths per minute (BPM).
Volume constant — Insures that each delivered breath will have essentially the same volume, independent of changes in patient compliance and airway resistance. The deliverable tidal volume (TV) range is from approximately 20ml to 3,000ml using 3 interchangeable bellows and bellows housings as seen here. Most small animal facilities require only the small bellows attachment , seen at the left, with the standard size ventilator, center.
Pressure Limited– Provides for patient safety by limiting the maximum working pressure (MWPL) to a user adjustable pressure range of 10 – 60 cm H2O. The Model 2002 was introduced after numerous customer requests for a finer volume adjustment at the low end of the range. We added a finer volume control in parallel with the existing control on the Model 2000. Everything else about the Model 2002 is identical to the Model 2000. Both ventilators are equipped with dual airway pressure alarms that monitor and sound when the peak inspiratory pressure (PIP) of any breath either exceeds the preset maximum working pressure limit (MWPL) or fails to reach 6 cm H2O as in the case of a disconnect . A Low Supply Gas Alarm available as an option, would sound when the supply gas pressure falls below 35 psi, 2.4bar. The normal supply gas operating pressure is 50psi or 3.5bar. It is not until 35psi or 2.4bar that the ventilators delivered volume will begin to drop off proportionally with the supply pressure. |
|
* NOTE: Above units include 0-300 ml bellows, housing and adapter.
Optional 300 -1600 ml bellows kit is priced at $350.00